Diesel power stations on electric units WILSON

  The Generation Industrial Group
Ðóññêèé Sitemap Faq
 
 

Industrial group “Generation” offers wide range of diesel power stations based on diesel-generators produced by F.G. Wilson

About company. .F.G Wilson company was found in 1996 in Belfast (Nothern Ireland) and now is one of largest European produces of diesel-generators with power up to 5,5 and 6500 kVA used as a main, standby or emergency power source for supply AC one phase (220/240V, 50/60Hz) or three phase (380/400V, 50/60Hz) current to different users

F.G. Wilson diesel generator sets equipped with internal combustion engine produced by Perkins, Scania, Kubota, Ford, Isuzu and bushless AC generator produced by Leroy Somer.

Power generators Wilson model range.

Engine type Designation: Power, kVA
Kubota

Ê

1phase: 5.5/6, 7/8, 6, 9; 3phase: 7/8, 9/10, 8, 12
Perkins

1phase: 10/11, 13/14, 15/16.5, 17.5, 18/20, 21/23, 24, 28, 27/30, 32/35, 36/40, 45/50, 56/62, 72/80, 80/88, 96/105
 

P

3phase: 12.5/13.5, 16.5/18, 20/22, 30, 35, 27/30, 40/44, 45/50, 60/65, 75/83, 90/100, 100/110, 135/150, 160/175, 188, 200/220, 230/250, 250/275, 450/500, 500/550, 563/625, 625/688, 910/1000, 1000/1100, 1250/1375, 1500/1650, 1700/1875, 1750/1925, 1825/2000, 2000/2200
Scania

SW, SL

 3phase: 225/250, 250/275, 300/330, 350/400, 400/450
Deutz

DZ

3phase: 390, 500, 650, 700, 750/845, 800, 900, 1000, 2000
    3phase: 2150, 2300, 2400, 2500 (high voltage 6,3 kW)
Paxman

PX

3phase: 2500, 3100, 3700 (high voltage 6,3 kW)

Power plant design.

 

All supplied production is in accordance to state standard of Russian Federation and have certiicated of conformity to GOST, and certificate os conformity to Electrosvyaz (Electrical connection) system.

Power units Wilson Perkins 400, 3 ph. 380 V, 50 Hz technical data

Model: Power: Rpm Fuel combustion, l/h TI panel model (option) Overall dimensions, l x w x h, mm Weight, kg
kVA

kW

P12,5P2

12,5

10 1500 3,7 ATI 63 1320x552x1258 402
P13,5E2

13,8

11 1500 4,1 ATI 63 1320x552x1258 402
P16,5P2

16,5

13,2 1500 4,5 ATI 63 1320x552x1258 462
P18E2

18

14,4 1500 5 ATI 63 1320x552x1258 462
P20P2

20

16 1500 5,4 ATI 63 1320x552x1258 475
P22E2

22

17,6 1500 6,1 ATI 63 1320x552x1258 475
PH22E2

22

17,6 3000 7,1 ATI 63 1320x552x1258 475
PH30E2

30

24 3000 9 ATI 63 1320x552x1258 475
PH35E2

35

28 3000 10,1 ATI 63 1320x552x1258 468

PERKINS 400, 1ph. 220V, 50Hz series

Model: Power: Rpm Fuel combustion, l/h TI panel model (option) Overall dimensions, l x w x h, mm Weight, kg
kVA

kW

P10P2S

10

10 1500 3,7 ATI 63 1320x552x1258 402
P11E2S

11

11 1500 4,1 ATI 63 1320x552x1258 402
P13P2S

13

13,2 1500 4,5 ATI 100 1320x552x1258 462
P14E2S

14

14,4 1500 4,3 ATI 100 1320x552x1258 462
P15P2S

15

16 1500 5,1 ATI 100 1320x552x1258 475
P16,5E2S

16,5

17,6 1500 5,8 ATI 100 1320x552x1258 475
P16,5E2S

17,5

17,6 3000 7 ATI 100 1320x552x1258 380
P16,5E2S

24

24 3000 10 ATI 125 1320x552x1258 446
PH28E2S

28

28 3000 10,1 ATI 125 1320x552x1258 468

Remarks to PERKINS series.

  1. 1.Weight and dimensional data are given for diesel generator open design
  2. 2. Fluid cooling system
  3. 3. All standard diesel generators are supplied as a complete set
    • Diesel generator mounted on bumpers on the frame with control system
    • Fuel tank with capacity of 45 l
    • Start dry-charged battery 12V with cables and clamps
    • Battery charging unit from house generator, 12V
    • Exhaust silencer
    • Outlet automated switch
    • Oil system and cooling system are filled with oil and antifreeze solution
    • Manual control panel LCP1 series providing following control, monitoring and protection functions
      • Outlet voltage voltmeter
      • Motometer
      • Battery voltmeter
      • “off/operation/start” key
      • Emergency stop button
      • Voltmeter phase selector switch
      • Lamp control button
      • High antifreeze temperature switch off
      • Low oil pressure switch off
      • Limiting current generator switch off
      • âûêëþ÷àòåëü ãåíåðàòîðà ïî ïðåäåëüíîìó òîêó.
  4. 4. Engine operation time between schedule service maintenance is increased to 500 hours

PERKINS series, 3 phase, 380V, 50Hz (1 500 rpm)

Model: Power: TI panel model (option) Standard control panel Fuel consumption, l/h Overall dimensions, l x w x h, mm Fuel tank capacity, l Weight, kg
êVÀ

êW

P27P1

27

21,6 ATI 63 1001 6,2 1770x714x1368 144 800
P30E1

30

24 ATI 63 1001 6,9 1770x714x1368 144 800
P30Ð1

30

24 ATI 63 1001 6,9 1770x714x1368 144 810
P33E1

33

26,4 ATI 63 1001 7,6 1770x714x1368 144 810
P40Ð3

40

32 ATI 100 1001 9,4 2149x752x1366 175 890
P44E3

44

35,2 ATI 100 1001 10,3 2149x752x1366 175 890
P45Ð3

45

36 ATI 100 1001 10,6 2149x752x1366 175 910
P50E3

50

40 ATI 100 1001 11,9 2149x752x1366 175 910
P50Ð1

50

40 ATI 100 1001 11,8 2149x752x1366 175 910
P55E1

55

44 ATI 100 1001 13 2149x752x1366 175 910
P60Ð3

60

48 ATI 100 1001 13,8 2149x752x1366 175 960
P65E3

65

52 ATI 100 1001 15,1 2149x752x1366 175 960
P80Ð1

80

64 ATI 250 1001 18 2149x752x1366 175 1010
P88E1

88

70,4 ATI 250 1001 19,9 2149x752x1366 175 1010
P90

90

72 ATI 250 PWP10 20,7 2485x746x1435 230 1260
P100E

100

80 ATI 250 PWP10 23,7 2485x746x1435 230 1260
P100

100

80 ATI 250 PWP10 22,8 2485x746x1435 230 1260
P110E

110

88 ATI 250 PWP10 25,4 2485x746x1435 230 1260
P135

135

108 ATI 250 PWP10 31,2 2675x900x1460 290 1480
P150E

150

120 ATI 250 PWP10 34,4 2675x900x1460 290 1480
P150P1

150

120 ATI 250 PWP10 31,2 2675x900x1564 300 1535
P165E1

165

132 ATI 250 PWP10 33,5 2675x900x1564 300 1535
P200Í

200

160 ATI 400 PWP10 43,1 2953x1003x1718 350 2052
P220ÍE

220

176 ATI 400 PWP10 47 2953x1003x1718 350 2052
P230Í

230

184 ATI 400 PWP10 48,7 2953x1003x1718 350 2137
P250ÍE

250

200 ATI 400 PWP10 52,6 2953x1003x1718 350 2137
P250Í

250

200 ATI 400 PWP10 53,1 2953x1003x1718 350 2252
P275ÍÅ

275

220 ATI 630 PWP10 56,3 2953x1003x1718 350 2252
P350P3

350

280 ATI 630 PWP10 69,4 3601x1100x2065 791 3366
P400E3

400

320 ATI 630 PWP10 81,2 3601x1100x2065 791 3366
P400P3

400

320 ATI 630 PWP10 79,2 3601x1100x2065 791 3503
P450E3

450

360 ATI 800 PWP10 87,9 3601x1100x2065 791 3503
P450P3

450

360 ATI 800 PWP10 88,8 3700x1100x2143 928 3800
P500E3

500

400 ATI 800 PWP10 98,6 3700x1100x2143 928 3800
P500Ð3

500

400 ATI 1000 PWP10 97,2 3700x1100x2143 928 3920
P550E3

550

440 ATI 1250 PWP10 106,8 3700x1100x2143 928 3920
P550Ð1

550

440 ATI 1250 PWP10 106 4111x1536x2098 1350 4725
P605E1

605

484 ATI 1250 PWP10 118 4111x1536x2098 1350 4725
P635E1

635

508 ATI 1250 PWP10 124 4111x1536x2098 1350 4787
P600P1

600

480 ATI 1250 PWP10 116 4111x1536x2098 1350 4787
P660Å1

660

528 ATI 1250 PWP10 130 4111x1536x2098 1350 4787
P635Ð1

635

508 ATI 1250 PWP10 125 4111x1536x2098 1350 4870
P700E1

700

550 ATI 1250 PWP10 140 4111x1536x2098 1350 4870
P730P1

730

584 ATI 1250 PWP10 149,8 4280x1912x2277 1671 6170
P800E1

800

640 ATI 1250 PWP10 163,4 4280x1912x2277 1671 6370
Ð800P1

800

640 ATI 1600 PWP10 163 4280x1912x2277 1671 6370
P900E1

900

720 ATI 1600 PWP10 183,5 4280x1912x2277 1671 6370

Note:

  • -Without E index: uninterrupted working – 24 hours a day, overload 10% for an hour every 12 hours is allowed.
  • - With E index: standby mode without overload.

Model: Power: TI panel model (option) Standard control panel Fuel consumption, l/h Overall dimensions, l x w x h, mm Fuel tank capacity, l Weight, kg
êVÀ

êW

P910P1

910

728 ÀTI 1600 PWP10 194,7 4790x2036x2235 144 7378
P1000E1

1000

800 ÀTI 1600 PWP10 217,7 4790x2036x2235 144 7378
P1000P1

1000

800 TI 2000 PWP10 215,4 4790x2036x2235 144 7568
P1100Å1

1100

880 TI 2000 PWP10 241,5 4790x2036x2235 144 7568
P1250

1250

1000

TI 2000 PWP10 264,3 4685x1800x2532 175 9555
P1375E

1375

1100

TI 2000 PWP10 292,1 5374x1760x2462 175 9555
P1500

1500

1200 TI 2500 PWP10 306,9 5110x1800x2522 175 9980
P1650E

1650

1320 TI 2500 PWP10 343 5110x1800x2522 175 9980
Ð1700

1700

1360 TI 3200 PWP10 354,0 5815x2070x2550 175 14700
Ð1875Å

1875

1500 TI 3200 PWP10 391,9 5815x2070x2550 175 14700
Ð1750

1750

1400 TI 3200 PWP10 356,7 5725x2300x3020 175 15700
Ð1925Å

1925

1540 TI 3200 PWP10 397,8 5725x2300x3020 175 15700
Ð1825

1825

1460 TI 3200 PWP10 378,3 5725x2300x3020 175 15700
Ð2000Å

2000

1600 TI 3200 PWP10 419,6 5725x2300x3020 175 15700
Ð2000

2000

1600 TI 4000 PWP10 423,5 5725x2300x3020 230 15700
Ð2200Å

2200

1760 TI 4000 PWP10 474,1 5725x2300x3020 230 15700

Note:

  • Without E index: uninterrupted working – 24 hours a day, overload 10% for an hour every 12 hours is allowed.
  • With E index: standby mode without overload.
  • For models P330E-P1 650E at nominal load the operation not more than 500 hours a years is allowed.
  • DG completeness include the cost of outlet switch, silencer and exhaust pipe bellow.

Remarks to PERKINS series

  1. 1. Weight and dimensional data are given for diesel generator open design
  2. 2. Fluid cooling system
  3. 3. All standard diesel generators are supplied as a complete set
    • Diesel generator mounted on bumpers on the frame with control system
    • Fuel tank with capacity (up to P900E1)
    • Start dry-charged battery 12V (24V) with cables and clamps
    • Battery charging unit from generator, 12V (24V)
    • Exhaust silencer
    • Exhaust pipe flexible bellow (for P90, P72SP1 and more powerful models)
    • Three-phase generator limiting current switch (for Ð27 - Ð900Å1 models)
    • Diesel oil system is filled with oil
    • Air heater at start-up (for Ð27 - Ð150Å models)
  4. 4.Standard design diesel generators are supplied with series control panel.
  5. 4.1.4.1. Control panel 1001 series for manual control providing following control and monitoring functions
    • Switchable phase voltmeter, 7-positioned fro three-phase current
    • Switchable ammeter, 4-positioned for three-phase current
    • Tachometer and frequency counter combination
    • Operation-time counter (machine hours)
    • Oil pressure indicator
    • Battery voltmeter
    • Antifreeze temperature indicator
    • Air heating switch button (thermal start up)
    • Selector switch “On/Off/Heating/ Start up/ (Manual/Off)”
    • Emergency stop button
    • Lamp check/ locking reset key
    • Three-try start up timer
    • Fault lamp warning device
    • Stop at low oil pressure in lubrication system
    • Stop at failing start
    • Stop at antifreeze overheating in cooling system
    • Stop at rotation speed more than allowable
  6. 4.2 PWP10 series control panel for manual and automation control, providing following control and monitoring functions.
    • - LCD with contrast and highlighting regulation

    AC current measurement

    • Volts 3 phase (phase-to-phase and phase-to-earth)
    • Ampere (for each phase and average)
    • Frequency.

    DC current measurement

    • Battery voltage, volt
    • Number of operation hours
    • Water temperature in crank case (°Ñ or °F)
    • Lubrication oil pressure (pounds per square inch, kPa or bar)
    • Motor speed (rpm)

    Protection device

    • Start failure
    • Low oil pressure
    • High engine temperature
    • High/low battery voltage
    • Charger failure (if charger applicable)
    • Low engine speed/ overspeed
    • Absence of engine speed indication
    • 2 stand-by channel for failures
    • System-trouble log with 20 events registered (event name, number of engine operation hours at first appearance of event, number of engine operation hours at last appearance of event, frequency of event appearance)

    Control elements

    • 2 LEDs for status indication (1 – red at stop, 1- yellow for warning)
    • Start button and LED
    • Automotive mode and LED
    • Stop button and LED
    • Indicator test button
    • Emergency signal confirmation button
    • Menu navigation bar
    • Hot keys for engine and AC current parameters activation
    • All control module buttons and keys have touch feedback
    • Emergency stop button blocking
© 2008 "The Generation Industrial Group".
SiteActiv