Boiler plants UKM series based on KVGM and KSVA (VK) boilers

  The Generation Industrial Group
Ðóññêèé Sitemap Faq
 
 

Hot-water boiler plants advantages

  • Wide model range
  • Factory assembled ready to operation
  • Boiler modules while installing as one unit
  • Erection on site in tight schedule and at relatively low price
  • Possibility of multiple mounting and dismounting
  • Heat-insulated walls, floor and roof
  • Fuel, water and delivered heat metering unit
Enlarged water storage vessel
Automation system control devices
High transportability
Modern design

Boiler plant composition

  • Hot-water boiler
  • Forced-draft fan
  • Induced-draft fan
  • Main-line pump
  • Make-up pump
  • Water treatment station
  • Water storage tank
  • Heating station mud-box
  • Operator’s room (serviced boiler)
  • Switchboard room

Boiler plant model range

  • UKM-1,1 V-G(1 boiler KVGM-1,1)
  • UKM-1,1 V-G(1 boiler KVGM-1,1)
  • UKM-2,2 V-G (2 boilers KVGM-1,1)
  • UKM-2,5 V-G (1 boiler KVGM-2,5)
  • UKM-4 V-G-M/ÁÊÒÂÓ-4,0Ã (2 boilers KSVA-2)
  • UKM-5 V-G (2 boilers KVGM-2,5)
  • UKM-7,5 V-G (3 boilers KVGM-2,5)
  • UKM-10 V-G (4 boilers KVGM-2,5)
  • UKM-12 V-G-M(4 boilers KSVA-3)

Technical data

Index: UKM-1,1 V-G UKM-2,2 V-G UKM-2,5 V-G UKM-4 V-G/V-M UKM-5 V-G UKM-7,5 V-G UKM-10 V-G UKM-12 V-G-M
Heat efficiency, MW (gigacalories/h) 1,1 (0,946) 2,2 (1,89) 2,5 (2,15) 4,0 5,0 (4,3) 7,5 (6,45) 10,0 (8,6) 12 (10,3)
Boilers number 1 2 1 2 2 3 4 4
Heat-transfer medium pressure, MPa (kgf/cm2) to 1,0 (10,0) to 1,0 (10,0) to 1,0 (10,0) to 0,6 to 1,0 (10,0) to 1,0 (10,0) to 1,0 (10,0) to 11,0
Fuel natural gas, light furnace oil, boiler oil, oil
Design efficiency, % 93 93 93 91 93 93 93 93
Water temperature, ºC:  
Inlet temperature, at least 70 70 70 70 70 70 70 70
Outlet temperature, at most 95 95 95 115 95 95 95 115
Overall dimensions, m:
length
11,82 11,82 11,82 11,82 11,82 11,82 11,82 11,82
width 6,48 9,64 6,48 6,40 9,64 12,88 16,12 9,60
height 3,10 3,10 3,10 3,20 3,10 3,10 3,10 3,20
Block-module quantity 2 3 2 2 3 4 5 3

Standart plant completing

  1. KGVM-1,1-95 boiler
  2. Burner
  3. Heat FD fan, capacity – 1,2 MW
  4. Water-preparation plant
  5. Make-up pump
  6. Main line pump
  7. Chemically treated water
  8. Mud box
  9. Custom design

  10. Accommodation area
  11. Heating station
  12. Circulation pump
  13. Main-line pump
  14. Electric service panel
  15. Plate heat exchanger

Certificate of conformity ¹ ÐÎÑÑ RU. MX05. BOO146.

Factory assembled plant modules

  • Gas fueled boiler unit modules
  • Pump modules
  • Water treatment module
  • Accommodation module
Modules connected on site represent small-size premises with boiler and auxiliary equipment and automation mounted inside.

Modules are made with panel-framed structure. Panels covered with thin shaped metal sheets are fixed on the steel frame. Heat insulation is performed by means of hard mineral wool boards, thickness – 80mm, with synthetic binder. Modules are connected in block on the longer side. Joints are packed with sealing material and covered with dismountable covering at place of erection.

Modules are transported without dismounting of installed equipment and connections by automobile transport (by trailer truck), railroad transport, water and air transport (by helicopters). Modules have electrical lighting. There is one gas fueled KVGM boiler unit with heating capacity 1.1 or 2.5 MW or VK-21 boilers with oil, boiler oil or gas fuel. Automation system provides start and stop of the boiler units, two-position control (40 and 100%) or smooth heat capacity control and protection when the selected operation mode is disturbed. Every boiler is connected with the metal stack by the gas glue. Boiler plant heat capacity can be increased by connecting extra boiler unit modules.

© 2008 "The Generation Industrial Group".
SiteActiv