Automated tubular oil heater PT-6,3/200, PT-16/150, PT-25/100

  The Generation Industrial Group
Ðóññêèé Sitemap Faq
 
 
Usage

Automated tubular oil heaters are intended for heating of oil, oil emulsions and gas in oil\gas fields systems at field transportation. Climatic construction “U1” in accordance with GOST 15150.

Technical specifications

Parameters
PT-6,3/200 PT-16/150 PT-25/100
Working pressure, MPa 200 150 100
Nominal diameter, mm Outlet oil temperature, °Ñ, not less than +5 +5 +5
Inlet oil temperature, °Ñ, not less than +90 +90 +90
Oil rate, t/hour, not more than 98 42 12
Heat power, MW, not less than 4,2 1,9 0,5
Fuel gas pressure at heater inlet, MPa, not more than 1,0 1,0 1,0
Gas pressure before burners, MPa, not more than 0,15 0,15 0,15
Gas flow rate, m2/hour, not more than 644 306 76
Efficiency, %, not less than 65 65 65