U-tube heat exchangers

  The Generation Industrial Group
Ðóññêèé Sitemap Faq
 
 

Shell diameter, mm Pressure, Py, MPa
Ðó, ÌPà
Heat-exchange area, m2 w/tubes Ø20 L, mm Í, mm Dó, mm À, mm À1, mm l0, mm l1, mm S0, mm
325 2,5 15,0
29,5
 3800
6800
600
600
 100
100
 450
450
2500
5500
1500
3000
400
1100
 330
426 2,5  31,0
64,0
3940
6940
 714
714
 100
100
500
500
2500
5500
 1500
3000
400
1100
 330
530 2,5 49,5
95,0
4070
7070
 954
954
 150
150
 550
550
 2500
5500
 1500
3000
 400
1100
 380
630 1,6; 2,5  144,0 7225
 1060  200 600
 5400  3000  1100  450
800 1,6 274,0
411,0
7300
10300
1354
1354
250
250
700
700
5400
8400
3000
6000
1450
1450
500
2,5 274,0
411,0
7315
10315
1354
1354
250
250
700
700
5400
8400
3000
6000
1450
1450
4,0 274,0
411,0
7360
10360
1354
1354
250
250
700
700
5400
8400
3000
6000
1450
1450
1000 1,6 447,0
672,0
7625
10625
1558
1558
300
300
750
750
5500
8500
3000
6000
1450
1450
800
2,5 447,0
672,0
7625
10625
1558
1558
300
300
750
750
5500
8500
3000
6000
1450
1450
1200 1,6 651,0
961,0
7720
10720
1780
1780
300
300
800
800
5400
8400
3000
6000
1400
1400
 
2,5 651,0
961,0
7800
10800
1780
1780
300
300
850
850
5400
8400
3000
6000
1400
1400
1400 1,6 930,0
1369,0
8055
11055
1980
1980
350
350
1000
1000
5200
8200
3000
6000
1300
1300
950
2,5 930,0
1369,0
8075
11075
1980
1980
350
350
1000
1000
5200
8200
3000
6000
1300
1300

Note: Horizontal heat exchangers are designed to operate at 4,0; 6,3 MPa. Heat exchanger diameter of 630 mm is considered as outer diameter, the exceeding diameter is specified as internal diameter. In the same way, tube length 1 is applied for 3000, 6000 and 6000, 9000 mm. Apparatus can be produced with tubes diameters of 16, 20 and 25 mm.


Identification Example (for ordering):

U-tube heat exchanger 1000TU-1,6-M1/25-6-T
as per TU (Spec.) 3612-023-00220302-01 where

1000
shell diameter, mm;

ÒU
U-tube heat exchanger

1,6 – shell pressure, MPa;

Ì1 – material design;

25 – heat-transfer diameter, mm;

6 – tube length, m;

Ò – w/heat-transfer tubes arranged in sheet in equilateral-triangle way.

Square arrangement of heat-transfer tubes is available on request.

© 2008 "The Generation Industrial Group".
SiteActiv