| Shell diameter, mm | Pressure, Py, MPa Ðó, ÌPà |
Heat-exchange area, m2 w/tubes Ø20 | L, mm | Í, mm | Dó, mm | À, mm | À1, mm | l0, mm | l1, mm | S0, mm |
| 325 | 2,5 | 15,0 29,5 |
3800 6800 |
600 600 |
100 100 |
450 450 |
2500 5500 |
1500 3000 |
400 1100 |
330 |
| 426 | 2,5 | 31,0 64,0 |
3940 6940 |
714 714 |
100 100 |
500 500 |
2500 5500 |
1500 3000 |
400 1100 |
330 |
| 530 | 2,5 | 49,5 95,0 |
4070 7070 |
954 954 |
150 150 |
550 550 |
2500 5500 |
1500 3000 |
400 1100 |
380 |
| 630 | 1,6; 2,5 | 144,0 | 7225 |
1060 | 200 | 600 |
5400 | 3000 | 1100 | 450 |
| 800 | 1,6 | 274,0 411,0 |
7300 10300 |
1354 1354 |
250 250 |
700 700 |
5400 8400 |
3000 6000 |
1450 1450 |
500 |
| 2,5 | 274,0 411,0 |
7315 10315 |
1354 1354 |
250 250 |
700 700 |
5400 8400 |
3000 6000 |
1450 1450 |
||
| 4,0 | 274,0 411,0 |
7360 10360 |
1354 1354 |
250 250 |
700 700 |
5400 8400 |
3000 6000 |
1450 1450 |
||
| 1000 | 1,6 | 447,0 672,0 |
7625 10625 |
1558 1558 |
300 300 |
750 750 |
5500 8500 |
3000 6000 |
1450 1450 |
800 |
| 2,5 | 447,0 672,0 |
7625 10625 |
1558 1558 |
300 300 |
750 750 |
5500 8500 |
3000 6000 |
1450 1450 |
||
| 1200 | 1,6 | 651,0 961,0 |
7720 10720 |
1780 1780 |
300 300 |
800 800 |
5400 8400 |
3000 6000 |
1400 1400 |
|
| 2,5 | 651,0 961,0 |
7800 10800 |
1780 1780 |
300 300 |
850 850 |
5400 8400 |
3000 6000 |
1400 1400 |
||
| 1400 | 1,6 | 930,0 1369,0 |
8055 11055 |
1980 1980 |
350 350 |
1000 1000 |
5200 8200 |
3000 6000 |
1300 1300 |
950 |
| 2,5 | 930,0 1369,0 |
8075 11075 |
1980 1980 |
350 350 |
1000 1000 |
5200 8200 |
3000 6000 |
1300 1300 |
Note: Horizontal heat exchangers are designed to operate at 4,0; 6,3 MPa. Heat exchanger diameter of 630 mm is considered as outer diameter, the exceeding diameter is specified as internal diameter. In the same way, tube length 1 is applied for 3000, 6000 and 6000, 9000 mm. Apparatus can be produced with tubes diameters of 16, 20 and 25 mm.
Identification Example (for ordering):
U-tube heat exchanger 1000TU-1,6-M1/25-6-T as per TU (Spec.) 3612-023-00220302-01 where
1000 – shell diameter, mm;
ÒU – U-tube heat exchanger
1,6 – shell pressure, MPa;
Ì1 – material design;
25 – heat-transfer diameter, mm;
6 – tube length, m;
Ò – w/heat-transfer tubes arranged in sheet in equilateral-triangle way.
Square arrangement of heat-transfer tubes is available on request.