'Pipe-in-pipe' heat exchangers

  The Generation Industrial Group
Ðóññêèé Sitemap Faq
 
 
Technical specification

Parameters  Parameter values for heat exchanger type:
 TTON  TTOR  TTM  TTRM
 Heat exchange area, m2  0,11–4,45  5,0–18,0  3,9–93,0 0,55–4,6
Tubes design material Ã, ÏÐ, Ø Ã Ã, ÏÐ, Ø Ã, ÏÐ, Ø
Heat-transfer tube outer diameter, mm 25, 38, 48, 57, 89, 108, 133, 159 89, 108, 133, 159 38, 48, 57 25, 38, 48, 57
Shell tube outer diameter, mm 57, 76, 89, 108, 133, 159, 219 133, 159, 219 89, 108 57, 76, 89, 108
Nominal pressure, MPa, max. tubes
shell
1,6; 4,0; 6,3; 10,0; 16,0
1,6; 4,0; 6,3; 10,0
1,6; 4,0
1,6; 4,0
1,6; 4,0
1,6; 4,0
6,3; 10,0; 16,0
1,6; 4,0; 6,3; 10,0
Working medium temperature, °Ñ tubes
shell
– 30 äî +300
– 30 äî +400
– 30 äî +400
– 30 äî +400
– 30 äî +400
– 30 äî +400
– 30 äî +400
– 30 äî +400
Heat-transfer tubes, mm 1500, 3000, 4500, 6000, 9000 4500, 6000, 9000 3000, 4500, 6000, 9000 1500, 3000, 4500,6000


Identification Example (for ordering):

TTON-2-57/108-6,3/4,0/6-G-M1-U as per TU (Spec.) 3612-014-00220302-99, where

'Pipe-in-pipe' single-flow heat-exchanger (TTON),

2 – design;

57/108 – shell and tube diameters;

6,3/4,0 – outer and internal nominal pressure (heat-transfer tubes;

à – heat-transfer tubes, plain, length 6 m;

Ì1 – material design;

Ó – climatic design.
© 2008 "The Generation Industrial Group".
SiteActiv